This manual provides detailed information on the features, functions, installation, wiring, testing, etc. of the LN3 series stepper motors and drives.
The LN3 Series Motor and Drives Operator's Manual describes the Precision Motion Controls LN3 drive, a microstepping drive with a linear amplifier output stage for stepping motor applications where motor vibration must be minimized and EMI noise cannot be tolerated. The drive provides smooth movement with microstepping resolution up to 51200 steps/revolution and can be purchased with motors with torque ranging between 60 and 400 in-oz.
The manual covers unpacking, mounting, cooling, motor and line power connections, indexer connections, dip switch settings, test mode, auto-standby, fault indicators, electrical specifications, motor compatibility, indexer inputs, resonances, and an appendix with LN3 specifications. It also states a one-year warranty against manufacturing defects from the date of purchase.
| Drive type | Microstepping drive with linear amplifier output stage |
|---|---|
| Microstepping resolution | Up to 51200 steps/revolution |
| Motor torque range | 60 to 400 in-oz |
| Step input rate | 2 MHz |
| Selectable step sizes | 8 |
| Input power | 95 to 132 VAC 50/60 Hz; 190 to 270 VAC 50/60 Hz, switch selectable |
| Fuse | 2 3.5 Amp 250V |
| Output power | 0 to 2.5 Amps at 40 VDC through an H bridge liner driver |
| Motor inductance (PMC supplied) | Approximately 4 mH |
| Minimum motor inductance | 1 mH |
| High motor inductance effect | Greater than 20 mH reduces top motor speed |
| Ambient temperature | Should not exceed 40 degrees C |
| Auto-standby current | Reduces motor current to 1/2 after about 2 seconds |
| Fault current threshold | 7 Amps |
| Fault voltage threshold | 90 VAC |
| Fault temperature threshold | 50 degree C |
| Warranty | One year against manufacturing defects from date of purchase |
Fault1 indicates an over-current or over-temperature condition; power must be turned off and back on for the drive to continue operation.
Fault2 indicates that current is not on the motor, meaning the shutdown signal is active.
Auto-standby mode is activated by putting switch 1-7 in the off position.
In test mode, the motor rotates at about 0.7 rev/second.