This document is an electric water heater installation manual, which introduces the installation process, including electric circuit connection and water pipe connection
This manual provides installation and operation instructions for SioGreen tankless electric water heaters, specifically models IR-30, IR-234, IR-245, IR-260, IR-288, IR-14K220, and IR-18K220. The document details safety precautions, unit operation principles involving quartz heating tubes, and specific requirements for indoor installation.
| Maximum Flow Rate (IR-30) | 1.0 GPM |
|---|---|
| Maximum Flow Rate (IR-260) | 3.0 GPM |
| Maximum Flow Rate (IR-18K220) | 4.0 GPM |
| Maximum Power (IR-18K220) | 18.0 KW |
| Minimum Breaker (IR-14K220) | 60 AMP |
| Minimum Wire (IR-18K220) | 2 x 4 AWG |
The water heater's thermostat should not be set above 120°F to prevent serious scalding or death.
No, the product should be installed indoors only, unless mounted in a suitable enclosure that protects it from all-weather elements.
The unit requires no maintenance, but it is recommended to use an inlet pre-filter and check/clean it periodically.