This is an installation manual that introduces the various things to keep in mind when installing the product, including temperature and humidity, space size, accessory checks, and ventilation.
This Setup Guide from Roland DG Corporation covers installation and initial configuration of the TrueVIS LG-640, LG-540 and LG-300 machines. It begins with the checks to perform before installation: the documentation supplied with the machine, deciding on a suitable installation site, the permitted temperature and humidity ranges, required installation space and air ventilation, and the items included in the package. The document states that placement and installation must be carried out by suitably qualified workers and that transportation and emplacement should be entrusted to trained professionals.
The second part walks through the physical installation in numbered steps: assembling the stand, attaching the printer unit to the stand, installing the media holders and media stays, assembling the media take-up unit, installing the drain bottle, removing the retainers, affixing the labels, connecting the cable, preparing the cleaning liquid and ink, and performing initial settings and ink filling. Later sections cover assembly and installation of the cutting tool, network settings including a fixed IP address and a direct computer connection, downloading and installing Roland DG Connect Hub and the software RIP, installation of ventilating equipment, and the appendix with the power rating and serial number label location and specifications.
| Operating temperature | 20 to 32 °C (68 to 89.6 °F) |
|---|---|
| Operating humidity | 35 to 80 %RH (no condensation) |
| Non-operating temperature | 5 to 40 °C (41 to 104 °F) |
| Total machine weight | up to 262 kg (578 lb.); 54-inch model 241 kg (532 lb.), 30-inch model 206 kg (455 lb.) |
| Installation space, LG-640 | A: 4,500 mm (177.2 in.), B: 3,500 mm (137.8 in.) |
| Maximum instantaneous blade force | 500 gf |
| Warm-up time after power up | 5 to 20 minutes |
The machine must be used at 20 to 32 °C (68 to 89.6 °F) with 35 to 80 %RH and no condensation.
Placement and installation must be performed by suitably qualified workers, and transportation, unloading and emplacement should be entrusted to trained professionals.
The Setup Guide and User's Manual can be viewed and downloaded from the Roland DG download center link given for the LG-640.
The guide lists checks before installation, including an installation site that is level and stable, adequate ventilation, and the included items.