Describes how to install the wired remote and provides Quartz™ and Rise™ product components
This guide explains how to install an Aqualisa wired remote for Visage™, Viso™, Zuri™, iSys™, Quartz™ and Rise™ shower systems. It lists the components supplied with each remote variant, gives the safety and compliance information that applies to all remotes, and describes where the remote may be sited – inside the showering area provided it is not subjected to continuous spray, or up to 10 metres from the Quartz Smart Valve™.
The document includes single and dual outlet wiring diagrams for Quartz™ and Rise™, advice on avoiding digital TV interference, and step-by-step instructions for routing the 10m low voltage data cable, fixing the back plate and locking the remote in place. It ends with commissioning steps, a short user guide for single and dual outlet systems, and cleaning and maintenance notes.
| Data cable length | 10 m low voltage data cable |
|---|---|
| Maximum distance from Quartz Smart Valve™ | up to 10 metres |
| Ambient temperature range | 5 ºC to 40 ºC |
| Recommended cable length at remote side | minimum 70 mm including connector plug |
| Rear cable entry hole | Ø20 mm |
| Fixing screws | no. 8 non-rusting countersunk head screws |
| Guarantee | 1 year, upgradable by registering the product |
It can be sited outside the showering area up to 10 metres from the Quartz Smart Valve™.
No. Controllers and remotes from different ranges are not cross compatible, for example iSys™ remotes only work with iSys™ controllers.
Push and hold the remote button for 3 seconds to stop the first outlet and start the second outlet.
Use only a soft cloth and washing up liquid, and do not use abrasive cleaners.