The portable flux observation system (PFOS) is a reference system for tower flux observations, which can perform sensible heat, water vapor, and CO2 flux measurements with the eddy-covariance method. This manual introduces the system configuration, configuration, measurement principle, usage, system performance parameters, etc. of PFOS.
This manual describes the portable flux observation system developed by the Forestry and Forest Products Research Institute for measuring sensible heat, water vapor, and CO2 flux using the eddy-covariance method. The system includes components such as an infrared gas analyzer (LI-7000), ultrasonic anemometer (CSAT3), and data logger (CR3000). It is designed for short-term, portable use and can be powered by 12V or 24V DC. The manual covers system components, setup, calibration, data recording, and system specifications.
| Dimensions and Weights | Not specified in text |
|---|---|
| Current Consumption | Not specified in text |
The system includes a closed-path infrared gas analyzer (LI-7000), ultrasonic anemometer (CSAT3), humidity and temperature sensor (HMP45A), data logger (CR3000), and flow-path control system.
The system can be powered by 12 V DC or 24 V DC, and can be connected to an AC power source via a 100–240 V AC input converter.