This manual is about the user manual for Conductix Side Contact product.
The Side Contact Manual 963100.3.0 describes Conductix side contact conductor bar systems and their installation. It lists safety instructions, required hand tools, hanger clamp and bracket assemblies, web-mounted conductors, typical straight-runway layouts, collector mounting, and expansion sections.
It also includes an index for operation, maintenance, troubleshooting, and replacement parts, along with anchor and sliding tight clamp torque values and expansion gap settings.
| Anchor tight clamp torque | 60 in-lbs |
|---|---|
| Sliding tight clamp torque | 30 in-lbs |
| Contact shoe pressure | 4 to 6 lbs |
| Hanger clamp spacing | 4 ft (3 ft on curves) |
| Minimum conductor centerline spacing | 1-3/8 in |
| Hanger clamp mounting torque | 8-12 ft-lbs |
The manual specifies 60 in-lbs for anchor tight conductor bar clamps.
Hanger clamps are designed to provide a sliding tight fit at 30 in-lbs.
Contact shoe pressure for all collectors is listed as 4 to 6 lbs.
Hanger clamp and bracket assemblies are mounted on steelwork at 4 ft, and at 3 ft on curves.