This is a product manual about temperature indicators
This technical guide covers COMEM temperature indicators for liquid and winding temperature measurement, including oil/IEC and air/ANSI versions, standard configurations, options, and technical data.
It also provides dimensions, mounting types, bulb details, electrical schemes, order sheet information, and overlapping switch arrangements.
| Ambient temperature | -40 °C to 80 °C (-40 °F to 176 °F) |
|---|---|
| Degree of protection | IP66 in accordance with EN60529 |
| Measuring accuracy | 1.5 % of Full Scale |
| Measuring range in oil / IEC | -50 °C / +150 °C, -20 °C / +140 °C, 0 °C / +150 °C, 0 °C / +160 °C |
| Measuring range in air / ANSI | 0 °C / +120 °C for ATI, eATI and 0 °C / +180 °C for ATIw, eATIw, AWTI, eAWTI |
| Standard | IEC 60076-22-1 |
| Nominal current availability | 1 A, 2 A and 5 A |
| PT100 | Max no. 2 ; 3 wires |
| Capillary length (ATI/AWTI) | up to 394'' (10 m) |
| Capillary length (OTI/WTI) | up to 18 m |
| Micro switches | 2 or 4 |
| Housing | Aluminum casting, RAL 7032, powder coated (C4) |
The indicators can be fitted with 2 or 4 adjustable change-over micro switches.
The degree of protection is IP66 in accordance with EN60529.
Measuring accuracy is 1.5 % of Full Scale.
Up to 2 PT100 sensors with 3 wires can be added.