This is a user manual for a metal detection system
This is the English translation of the user manual for the MESUTRONIC METRON 07 C, CI and SlimLine metal detection system (document version GB-MN07-M0-004, mode 0). It explains the operating principle of metal detection with transmitter and receiver coils, general notes on metal detection such as electromagnetic short circuits and electrostatic discharges, and the safety rules for operating the device as provided.
The manual covers transport, installation and storage, assembly and set-up tips for the AMD 07 electronic housing and the C-Coil, CI-Coil and SlimLine-Coil detectors, relay and supply voltage connection, and touch screen display operation. Adjustment chapters describe operating levels 1, 2 and QM including product learning, product memory, reject parameters, conveying speed, frequency, USB, system info, user manager, protocols and detector tests. Further chapters cover maintenance and cleaning, error messages, technical data, plug configuration, key plan and spare parts.
The seeker head creates and evaluates an electromagnetic field with transmitter and receiver coils; when a metal body enters the field the signal indication display deflects, and if both switching thresholds are reached, metal is detected.
At least one relay and a 24V output (output A1) are available for queries.
Only with a slightly moist, soft cloth, using a screen cleaning agent such as an antistatic foam cleaner; corrosive agents, scouring agents and hard objects must not be used.