This manual introduces the use of Plasma 1880 LCD Inverter, including plasma cutting principle, plasma cutting system composition, the role of gas in plasma cutting and plasma cutting gas purity.
This Plasma Operating Manual from Elettro c.f. srl explains how a plasma cutting generator works and how to use it. It starts with the basics of plasma as the fourth state of matter, the components of a plasma arc cutting (PAC) system, the role and purity class of the cutting gas, and how cut quality relates to the direction of torch feed.
The manual then covers rules and characteristics for using a plasma cutting generator, the patented synergic plasma cutting method, cutting specifications for the Plasma 1880 LCD Inverter, electrical and pneumatic connections, CNC settings, practical tips and troubleshooting, common mistakes, the wiring diagram for the AMP 14-pin CNC connector, and cutting charts from 45 A to 180 A.
| Plasma pilot arc temperature | up to 30,000 °C |
|---|---|
| Generator output DC voltage | between 200 and 400 VDC |
| Common plasma current density | 12,000-20,000 A per square inch |
| High-density plasma current density | about 40,000-50,000 A per square inch |
| Cutting charts available | 45 A, 65 A, 85 A, 105 A, 125 A, 160 A, 180 A |
Plasma is the fourth state of matter, formed when enough gas atoms are ionized to significantly affect the electrical characteristics of the gas.
It consists of the cutting gas, the electrode (negative pole), the nozzle (positive pole), the cooling gas and the plate to be cut (positive pole).
Common plasma systems typically use only air as the feed gas and have a low current density, while high-density plasma has a current density of about 40,000-50,000 A per square inch for cleaner cuts and a reduced kerf.
The plasma pilot arc immediately reaches temperatures of up to 30,000 °C, rapidly penetrating the workpiece.