This is an instruction manual for KDS/BGK variable area flow meters. It introduces the features and usage methods of this product.
The KDS/BGK operating manual from Heinrichs Messtechnik describes the KDS-K/C/S, KDS-R and BGK variable-area flowmeters. It covers safety instructions, intended use, identification, applications, measuring principle and system design.
Further sections address measuring ranges, electrical output and connection, measuring accuracy, conditions of use, construction details, use in hazardous areas, maintenance and troubleshooting.
| Measured variable | Volume flow |
|---|---|
| Measuring range span | 10-100 % |
| Smallest measuring range | 0.1-1.0 l/h water |
| Largest measuring range (KDS-K/C) | 10-100 l/h water |
| Largest measuring range (KDS-S and BGK) | 20-200 l/h water |
| Largest regulator range (KDS-R) | 10-100 l/h water |
| Product type (KDS-K/C/S and BGK) | Miniature flowmeter in full-metal design based on the float principle |
They are intended for flow measurements of non-viscose fluid and gaseous media.
The smallest measuring range is 0.1-1.0 l/h water.
The product flows upward and lifts the float; the float height is a measure of the flow quantity.
It compensates pressure changes on the input or output side to keep the set flow rate constant; the other side must be stable.