Nachi NSP-10E-15V1A*-21 Series Frequency Inverter Hydraulic Station Product Leaflet

NSP-10E-15V1A*-21 series frequency inverter hydraulic station adopts frequency inverter technology, which is energy-saving and efficient. The output pressure range is wide, which can meet the needs of various working conditions.


Nachi NSP-10E-15V1A*-21 Series Frequency Inverter Hydraulic Station Product Leaflet - cover page
Brand
Nachi
Category
Other
Document type
Product Leaflet
Language
Chinese
Pages
1
File format
PDF
File size
51.7 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
DF270FD61196D69A2A5CE84FE26DD8DF

About this manual

The leaflet presents the NSP series frequency-inverter hydraulic station from Nachi. It lists supply voltage, rated input current, pressure adjustment ranges, no-load displacement, hydraulic oil, ambient conditions, model code, dimensions and approximate mass.

It also includes an installation dimension drawing, hydraulic circuit diagram, optional accessories and cautions for use. The document is identified by catalog number H9241C-3. This manual is written in Chinese.

What's inside

  • Specifications
  • Model code explanation
  • Installation dimension drawing
  • Hydraulic circuit diagram
  • Model, dimensions and approximate mass
  • Optional accessories
  • Cautions for use

Specifications

Power supply voltage3-phase AC 200–240 V, 50/60 Hz (200 V class); 3-phase AC 380–480 V, 50/60 Hz (400 V class)
Rated input current9.7 A / 1.5 kW, 13.4 A / 2.2 kW (200 V class); 5.9 A / 1.5 kW, 8.2 A / 2.2 kW (400 V class)
Pressure adjustment rangeA2: 1.5–4.0 MPa; A3: 3.5–6.0 MPa; A4: 5.5–8.0 MPa
Displacement at no load0A*: 14 L/min; 1A*: 28 L/min
Hydraulic oilGeneral mineral hydraulic oil, ISO VG32 equivalent
Oil temperatureUse below 60°C
Ambient temperature and humidity0–35°C / 20–85%RH, no mist
Tank capacity10 L or 20 L
Motor capacity1.5 kW or 2.2 kW
Maximum peak pressure14 MPa or less

Frequently asked questions

What pressure adjustment ranges are available?

A2 is 1.5 to 4.0 MPa, A3 is 3.5 to 6.0 MPa, and A4 is 5.5 to 8.0 MPa.

What is the no-load displacement for the 0A* and 1A* versions?

0A* provides 14 L/min and 1A* provides 28 L/min.

What hydraulic oil is specified?

The specified oil is general mineral hydraulic oil equivalent to ISO VG32.

What ambient conditions are allowed?

The allowed ambient conditions are 0–35°C and 20–85%RH with no mist.