NSP-10E-15V1A*-21 series frequency inverter hydraulic station adopts frequency inverter technology, which is energy-saving and efficient. The output pressure range is wide, which can meet the needs of various working conditions.
The leaflet presents the NSP series frequency-inverter hydraulic station from Nachi. It lists supply voltage, rated input current, pressure adjustment ranges, no-load displacement, hydraulic oil, ambient conditions, model code, dimensions and approximate mass.
It also includes an installation dimension drawing, hydraulic circuit diagram, optional accessories and cautions for use. The document is identified by catalog number H9241C-3. This manual is written in Chinese.
| Power supply voltage | 3-phase AC 200–240 V, 50/60 Hz (200 V class); 3-phase AC 380–480 V, 50/60 Hz (400 V class) |
|---|---|
| Rated input current | 9.7 A / 1.5 kW, 13.4 A / 2.2 kW (200 V class); 5.9 A / 1.5 kW, 8.2 A / 2.2 kW (400 V class) |
| Pressure adjustment range | A2: 1.5–4.0 MPa; A3: 3.5–6.0 MPa; A4: 5.5–8.0 MPa |
| Displacement at no load | 0A*: 14 L/min; 1A*: 28 L/min |
| Hydraulic oil | General mineral hydraulic oil, ISO VG32 equivalent |
| Oil temperature | Use below 60°C |
| Ambient temperature and humidity | 0–35°C / 20–85%RH, no mist |
| Tank capacity | 10 L or 20 L |
| Motor capacity | 1.5 kW or 2.2 kW |
| Maximum peak pressure | 14 MPa or less |
A2 is 1.5 to 4.0 MPa, A3 is 3.5 to 6.0 MPa, and A4 is 5.5 to 8.0 MPa.
0A* provides 14 L/min and 1A* provides 28 L/min.
The specified oil is general mineral hydraulic oil equivalent to ISO VG32.
The allowed ambient conditions are 0–35°C and 20–85%RH with no mist.