Marco Ecoboiler-Ecosmart UC4 UC10 Water Boiler Installation and Maintenance Service Manual

This file is Marco Ecoboiler Water boiler installation and maintenance manual.


Marco Ecoboiler-Ecosmart UC4 UC10 Water Boiler Installation and Maintenance Service Manual - cover page
Brand
Marco
Category
Water heater
Document type
Service Manual
Language
English
Pages
32
File format
PDF
File size
4.2 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
AC9E447BFA6429CB9440F88C9FAE2E45

About this manual

This service manual covers the Marco undercounter range: Ecoboiler UC4L 2.4 kW, Ecoboiler UC10L 2.8 kW, Ecoboiler UC10L 5.6 kW, Ecosmart UC4L 2.4 kW, Ecosmart UC10L 2.8 kW and Ecosmart UC10L 5.6 kW. It is dated August 2017 and lists Marco Beverage Systems Ltd. in Dublin, Ireland as the manufacturer.

The manual gives installation, operation, temperature calibration, time/volume dispense calibration, troubleshooting, maintenance, cleaning and limescale information, plus technical data. It states that only technicians or service providers authorised by Marco should carry out installation and maintenance.

What's inside

  • Introduction
  • Safety Instructions
  • Installation Details
  • Operation
  • Temperature Calibration
  • Time/Volume Dispense Calibration
  • Troubleshooting
  • Maintenance
  • Cleaning
  • Limescale

Specifications

Height394 mm
Width135 mm (UC4L); 226 mm (UC10L)
Depth585 mm
Immediate draw-off4 L (UC4L); 10 L (UC10L)
Maximum hourly output24 L/hr (UC4L); 28 L/hr (UC10L 2.8 kW); 56 L/hr (UC10L 5.6 kW)
Mains water pressure5–50 psi (35–345 kPa)
Plumbing fitting0.75” BSP with food-grade inlet hose supplied
Factory default set-point temperatureApproximately 94 °C

Frequently asked questions

What mains water pressure does the boiler require?

The required mains water pressure is 5–50 psi (35–345 kPa).

Is priming necessary before the boiler heats?

No. The boiler is electronically controlled, so no priming is necessary.

What does a cycle of two red flashes mean?

Two flashes indicate the water level is below the elements, which is normal when the machine first fills.

What should be used for descaling?

Use Scale Kleen, Marco part No. 8000270 or similar, and follow the instructions carefully.