This file is Marco Ecoboiler Water boiler installation and maintenance manual.
This service manual covers the Marco undercounter range: Ecoboiler UC4L 2.4 kW, Ecoboiler UC10L 2.8 kW, Ecoboiler UC10L 5.6 kW, Ecosmart UC4L 2.4 kW, Ecosmart UC10L 2.8 kW and Ecosmart UC10L 5.6 kW. It is dated August 2017 and lists Marco Beverage Systems Ltd. in Dublin, Ireland as the manufacturer.
The manual gives installation, operation, temperature calibration, time/volume dispense calibration, troubleshooting, maintenance, cleaning and limescale information, plus technical data. It states that only technicians or service providers authorised by Marco should carry out installation and maintenance.
| Height | 394 mm |
|---|---|
| Width | 135 mm (UC4L); 226 mm (UC10L) |
| Depth | 585 mm |
| Immediate draw-off | 4 L (UC4L); 10 L (UC10L) |
| Maximum hourly output | 24 L/hr (UC4L); 28 L/hr (UC10L 2.8 kW); 56 L/hr (UC10L 5.6 kW) |
| Mains water pressure | 5–50 psi (35–345 kPa) |
| Plumbing fitting | 0.75” BSP with food-grade inlet hose supplied |
| Factory default set-point temperature | Approximately 94 °C |
The required mains water pressure is 5–50 psi (35–345 kPa).
No. The boiler is electronically controlled, so no priming is necessary.
Two flashes indicate the water level is below the elements, which is normal when the machine first fills.
Use Scale Kleen, Marco part No. 8000270 or similar, and follow the instructions carefully.