Specifications of V90-PG series function expansion cards, including models, functions, applicable models, terminal signal definitions, etc.
This manual covers the Koyo V90-PG series function expansion cards used with V90 series inverters. It lists the model variants, their functions, applicable inverter models, and terminal signal definitions.
It also documents related parameters, including control mode selection, encoder pulse count, encoder type, AB phase sequence, encoder installation angle, rotary encoder pole pairs, and PG disconnection detection time. This manual is written in Chinese.
| Control mode selection P0.01 factory value | 2 |
|---|---|
| Encoder pulse count P1.27 factory value | 1024 |
| Encoder pulse count P1.27 setting range | 1 to 65535 |
| Encoder type P1.28 factory value | 0 (ABZ incremental encoder) |
| Encoder type P1.28 setting range | 0 (ABZ incremental encoder) or 2 (rotary transformer) |
| AB phase sequence P1.30 factory value | 0 (forward) |
| AB phase sequence P1.30 setting range | 0 forward, 1 reverse |
| Encoder installation angle P1.31 factory value | 0.0° |
| Encoder installation angle P1.31 setting range | 0.0° to 359.9° |
| Rotary encoder pole pairs P1.34 factory value | 1 |
| Rotary encoder pole pairs P1.34 setting range | 1 to 65535 |
| PG disconnection detection time P1.36 factory value | 0.0 s |
| PG disconnection detection time P1.36 setting range | 0.0 s (no action) or 0.1 s to 10.0 s |
The factory value 2 selects V/F control mode.
The factory value is 1024 pulses per revolution.
P1.28 supports ABZ incremental encoder (0) and rotary transformer (2).
The inverter does not detect encoder disconnection faults.