Koyo V90-PG Series Function Expansion Card Product Manual

Specifications of V90-PG series function expansion cards, including models, functions, applicable models, terminal signal definitions, etc.


Koyo V90-PG Series Function Expansion Card Product Manual - cover page
Brand
KOYO
Category
Expansion card
Document type
User Manual
Language
Chinese
Pages
11
File format
PDF
File size
436 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
88896088CD9BFF9AFA996C7AAAC9D0CB

About this manual

This manual covers the Koyo V90-PG series function expansion cards used with V90 series inverters. It lists the model variants, their functions, applicable inverter models, and terminal signal definitions.

It also documents related parameters, including control mode selection, encoder pulse count, encoder type, AB phase sequence, encoder installation angle, rotary encoder pole pairs, and PG disconnection detection time. This manual is written in Chinese.

What's inside

  • Model classification
  • Specifications and terminal signal definitions
  • PG-S1
  • PG-S2
  • PG-S3
  • PG-S5
  • PG-S8
  • PG-S10
  • MJ-S1
  • Related parameters

Specifications

Control mode selection P0.01 factory value2
Encoder pulse count P1.27 factory value1024
Encoder pulse count P1.27 setting range1 to 65535
Encoder type P1.28 factory value0 (ABZ incremental encoder)
Encoder type P1.28 setting range0 (ABZ incremental encoder) or 2 (rotary transformer)
AB phase sequence P1.30 factory value0 (forward)
AB phase sequence P1.30 setting range0 forward, 1 reverse
Encoder installation angle P1.31 factory value0.0°
Encoder installation angle P1.31 setting range0.0° to 359.9°
Rotary encoder pole pairs P1.34 factory value1
Rotary encoder pole pairs P1.34 setting range1 to 65535
PG disconnection detection time P1.36 factory value0.0 s
PG disconnection detection time P1.36 setting range0.0 s (no action) or 0.1 s to 10.0 s

Frequently asked questions

What control mode does the P0.01 factory value select?

The factory value 2 selects V/F control mode.

What is the factory value of encoder pulse count P1.27?

The factory value is 1024 pulses per revolution.

Which encoder types can be selected with P1.28?

P1.28 supports ABZ incremental encoder (0) and rotary transformer (2).

What happens when P1.36 is set to 0.0 s?

The inverter does not detect encoder disconnection faults.