Regency Kingston F3502B Freestanding Wood Fire Owners & Installation Manual

The owner’s manual introduces the features and usage methods of the Regency Kingston F3502B Freestanding Wood Fire


Regency Kingston F3502B Freestanding Wood Fire Owners & Installation Manual - cover page
Brand
Regency
Category
Heater
Document type
User Manual
Language
English
Pages
32
File format
PDF
File size
4.2 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
9CC4009D7C7119D58D34B77644B17E7E

About this manual

The Regency Kingston F3502B is a freestanding wood fire. This Owners & Installation Manual contains the safety label, unit dimensions, residential installation and modular installation options, minimum clearances to combustible materials, flue and connector installation steps, brick and fan installation, operating instructions, maintenance, and assembly information.

The manual states that installation must follow the instructions and applicable codes, and warns that improper installation can result in a house fire. It also instructs users to burn untreated wood only and includes maintenance items such as creosote, door gasket, glass, and the catalytic combustor.

What's inside

  • Safety Label for Kingston F3502B
  • Unit Dimensions
  • Residential Installation
  • Modular Installation Options
  • Minimum Clearance to Combustible Materials
  • Step-by-step Flue And Connector Installation
  • Brick Installation
  • Fan Installation
  • Operating Instructions
  • Maintenance

Specifications

ModelKingston F3502B
Maximum average heat output burning hardwood9.3 kW
Overall average efficiency burning hardwood84%
Flue diameter6 in (152 mm)
Minimum ceiling height for roof exit83 in (2108 mm)
Maximum alcove depth48 in (1219 mm)
Minimum alcove width60 in (1524 mm)

Frequently asked questions

What model does this manual cover?

It covers the Regency Kingston F3502B freestanding wood fire.

What should be burned in the F3502B wood fire?

Burn untreated wood only.

Can this unit be connected to a flue serving another appliance?

No. The manual says not to connect this unit to a flue serving another appliance.

What is the maximum average heat output burning hardwood?

The label lists a maximum average heat output burning hardwood of 9.3 kW.

Download PDF (4.2 MB)