Seng I-CORE JJZ(Y/T)-D3ZK-E Integrated Cooking Appliance User Manual

This is the instruction manual for SENG integrated range hood, which mainly introduces the product function, use method and installation instructions.


Seng I-CORE JJZ(Y/T)-D3ZK-E Integrated Cooking Appliance User Manual - cover page
Brand
森歌 (Seng)
Category
Range hoods
Document type
User Manual
Language
Chinese
Pages
10
File format
PDF
File size
797 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
C8C74B23CDA8C633350ACDA75EEFF1A2

About this manual

This is the Chinese user manual for the Seng (森歌) I-CORE integrated cooking appliance, covering models JJZ(Y/T)-D3ZK-E and JJZR-D3ZK-E. It was published by Zhejiang Seng Electronic Appliance Co., Ltd. and opens with a thank-you note, a warning that gas stoves have a scrap age of 8 years, and a table of contents.

The body of the manual gives the main technical parameters, explains the switch and keypad operation, introduces the eight cooking modes plus one-key disinfect and one-key ferment, and describes ignition, flameout and flame adjustment for the gas burners. It also contains the installation instructions with cabinet side-panel cutout and overall dimension reference tables, safety notices and daily maintenance notes for the steam oven, troubleshooting, maintenance and repair guidance, the service commitment and the list of supplied accessories. The appliance can be fitted with a Tmall Genie voice module, which requires a 2.4 GHz Wi-Fi network for setup. This manual is written in Chinese.

What's inside

  • Main technical parameters
  • Switch and button operation
  • Function mode introduction
  • Ignition, flameout and adjustment
  • Product installation instructions
  • Overall installation dimensions
  • Steam oven safety notices
  • Steam oven daily maintenance
  • Troubleshooting
  • Maintenance and repair

Specifications

ModelsJJZ(Y/T)-D3ZK-E; JJZR-D3ZK-E
Rated voltage / frequency220 V, 50 Hz
Rated gas pressureManufactured gas 1000 Pa; LPG 2800 Pa; natural gas 2000 Pa
Rated heat load (left / right)4.0 kW / 4.0 kW and 4.5 kW / 4.5 kW for the two listed models
Air volume16.5 m³/min
Max static pressure / pressure at rated airflow370 Pa / 520 Pa
Noise (sound pressure / sound power)54 dB(A) / 68 dB(A)
Steam oven rated input power3200 W
Steam oven cavity volume66 L
Water tank volume1.4 L
Product dimensions900 × 600 × 1272 mm

Frequently asked questions

How long should the knob be pressed when igniting a model with flameout protection?

After the burner lights, keep the knob pressed for another 3 to 5 seconds so the thermocouple heats up and the flameout safety device engages before you release it.

How do I switch the child lock on and off?

In standby or working state, press the child lock key for two seconds; all other keys are then locked. Press it again for two seconds to release the lock.

What network does the voice control module need?

The Tmall Genie module needs a 2.4 GHz Wi-Fi network, and the Wi-Fi name should preferably be in English.

How long can the gas stove be used before it must be scrapped?

Under GB 17905-2008 the scrap age of a gas stove is 8 years from the date of sale.