This document is the instruction manual for Bristan electric shower, which introduces the features, specifications, installation, operation methods and other information of the product.
The Bristan CHE85 W and CHE95 W electric showers are supplied with installation instructions and a user guide. The booklet covers safety information, product features, specifications, electrical and water requirements, wall fixing, plumbing and electrical connections, commissioning, operation, maintenance and troubleshooting.
The shower is intended for mains cold water pressure only and must be connected to a 230-240V AC supply. Installation must comply with current I.E.E Wiring Regulations (BS7671) and Building Regulations (Part P and Part G), and Bristan recommends installation by a suitably qualified person.
| Model | CHE85 W, CHE95 W |
|---|---|
| Declared Load Profile | XS |
| Water Heating Energy Efficiency Class | A |
| Water Heating Energy Efficiency | 38.6% (CHE85 W); 38.4% (CHE95 W) |
| Annual Electricity Consumption | 478 kWh (CHE85 W); 481 kWh (CHE95 W) |
| Sound Power Level | 15 dB |
| Inlet connection | 15 mm push fit |
| Outlet connection | 1/2” BSP male threaded |
| Minimum working pressure | 0.07 MPa (0.7 bar) |
| Maximum working pressure | 1.0 MPa (10 bar) |
| Minimum inlet water temperature | 5°C |
| Maximum inlet water temperature | 20°C |
| Electrical rating at 240 V / 230 V | 8.5 kW / 7.8 kW; 9.5 kW / 8.7 kW |
The instructions cover the CHE85 W and CHE95 W electric shower models.
The shower must only be connected to a 230-240V AC supply.
Yes. The circuit must incorporate a residual current device (RCD) with a tripping current of 30mA.
Turn off at the mains electrical supply and refer to the Troubleshooting section or contact Bristan Customer Services.