AMAZONE AMASET+ Control Box Operation Manual

This document is the operation manual of AMASET+ control box, which introduces the overview, compliant use, structure and function, debugging, settings, use, fault and maintenance of the product.


AMAZONE AMASET+ Control Box Operation Manual - cover page
Brand
Amazone
Category
Agricultural Machinery
Document type
User Manual
Language
Chinese
Pages
16
File format
PDF
File size
951 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
5A1D1AF14CEF15886F116698274488AC

About this manual

This operation manual for the AMAZONE AMASET+ control box covers user notices, general safety notes, product description, structure and function, commissioning, settings, machine operation, faults, and maintenance. It explains the display, switches, buttons, optional configuration buttons, spray pressure adjustment, and boom section control.

The AMASET+ control box is intended for display, monitoring, and control of AMAZONE UF01 crop protection sprayers equipped with an equal-pressure gauge. The document also gives operating steps and notes for spray pressure, tractor gear selection, pump drive speed, and troubleshooting. This manual is written in Chinese.

What's inside

  • User notices
  • General safety notes
  • Product description
  • Structure and function
  • Commissioning
  • Settings
  • Machine operation
  • Faults
  • Maintenance, repair and care

Specifications

Operating speed6 - 8 km/h
Pump motor speedMinimum 350 rpm, maximum 550 rpm
Spray pressure example0.32 MPa set; 0.24 to 0.40 MPa allowed
Spray table conversion for AHLMultiply values by 0.88

Frequently asked questions

What is the AMASET+ control box used for?

It is designed as a display, monitoring, and control device for AMAZONE UF01 crop protection sprayers with an equal-pressure gauge.

How do I connect the AMASET+?

Connect the machine plug to the AMASET+.

What should I check if the spray pressure cannot be set?

Check the power supply; a power interruption is listed as the cause.

How often should the equal-pressure gauge be adjusted?

Once a year.