SEA Marconi RT/HSDGA-20V II HS-DGA Revolving Table User's Manual

This manual introduces the components, use methods, precautions and other information of the HS-DGA REVOLVING TABLE RT/HSDGA-20V II system.


SEA Marconi RT/HSDGA-20V II HS-DGA Revolving Table User's Manual - cover page
Brand
SEA Marconi
Category
Other device
Document type
User Manual
Language
English
Pages
7
File format
PDF
File size
178 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
BAF1797A18E6090AF4744176A016786A

About this manual

The SEA Marconi RT/HSDGA-20V II HS-DGA Revolving Table has been developed to optimize the sample preparation step of insulating liquids for DGA (Dissolved Gas Analysis) with Head Space technique. It handles samples under inert gas flow and controlled atmosphere, reducing interferences from air gases, and is suitable for insulating mineral oils, synthetic insulating liquids, askarels, and silicones.

The system consists of a turning drum with 20 seats for 20 ml headspace vials inside a transparent canister. Setup requires placing the equipment on a firm workbench under a fume evacuation hood and connecting the inert gas delivery hose to the Gas inlet point on the front panel.

What's inside

  • Generals
  • System description
  • Set up of the system
  • Use
  • Notes
  • Enclosure

Specifications

Materialtransparent plexigass, delrin, stainless steel AISI 304
SizeØ 350mm, h. 240mm
Weight8 Kg
Vial capacity20 seats for 20 ml headspace vials

Frequently asked questions

What is the Revolving Table used for?

It has been developed to optimize the sample preparation step of insulating liquids for DGA with Head Space technique.

How many samples can be prepared per man-hour?

20 samples can be prepared per one man-hour, even by non-skilled personnel.

What flow rate is used for the initial Argon flushing?

Open the high-flow flowmeter at a flow rate of 40 to 60 l/min and flow for 10 minutes.