This manual describes the basic functions and operation of the OETIKER ELK 02 V2.X electrically controlled pneumatic pincer, including safety warnings, design features, operating instructions, and connection methods
OETIKER ELK 02 V2.X is an electronically controlled pneumatic pincer system used with HO-EL pincers. The manual covers safety, assembly, connection, operation, PC program and device menus, maintenance, troubleshooting, technical data, and warranty.
It describes new features of the V2.X control unit, including disabled user keys, dual closure, and revised individual closure data. The document also includes interface specifications, maintenance intervals, repair checklists, and disposal information.
| Power supply range | 85 - 265 V, 47 - 63 Hz |
|---|---|
| Power consumption | 30 VA |
| Recommended backup fuse | 10 A |
| X2 input nominal voltage | DC 24 V |
| X2 signal 0 range | 0 ... 5 V |
| X2 signal 1 range | 15 - 30 V |
| X2 input current | 10 mA (at 24 V) |
| X2 output operating voltage | DC 24 V (max. 30 V) |
| X2 lamp/relay output current | < 100 mA |
| X2 PLC output current | < 10 mA |
| Graphic display | 65x35 mm |
| Active program numbers | 99 |
| USB interface | Type B, galvanically isolated |
| X3 interface | RS232, galvanically isolated |
It applies to all HO-EL pincers with the ELK 02 V2.x control unit.
The power supply range is 85 to 265 V at 47 to 63 Hz.
The ELK 02 can store 99 active program numbers.
The power consumption is 30 VA.