This file is the manual of ZT-Mains-H5 AC/DC heat alarm.
This user manual provides step-by-step instructions for installing, testing, and maintaining the Zeta ZT-Mains-H5 AC/DC heat alarm. It includes safety precautions, installation guidelines for residential settings, and details on battery and mains power operation. The manual also explains how to test the alarm, handle low battery alerts, and perform weekly and annual maintenance.
The device is designed for residential use only and does not detect smoke, gas, or flame. It is not suitable for sleeping areas or non-residential buildings. Interconnection of up to 25 units is supported where fitted, with a maximum cable length of 250 meters.
| Mains power source | AC 220 V ~ AC 240 V, 50/60 Hz |
|---|---|
| Battery power source | DC 9 V |
| Operating temperature | 0 °C ~ +49 °C |
| Operating humidity | 10 % ~ 90 % RH, non-condensing |
| Alarm sounder output | ≥ 85 dB @ 3 m |
| Interconnection (max) | 25 units, 250 m cabling |
No, heat alarms should not replace required smoke alarms in sleeping areas.
Up to 25 units can be interconnected as long as the cabling is less than 250 m in length.
The heat alarm will emit a short audible signal every 32 s for at least 30 days.
The operating temperature range is 0 °C to +49 °C.