Metso Neles Series GW 3-Way Globe Control Valve Technical Bulletin GW 24 EN

Metso GW series 3-way guided globe valves combine the benefits of strong guidance with an unbalanced trim design. The primary application is temperature control.


Metso Neles Series GW 3-Way Globe Control Valve Technical Bulletin GW 24 EN - cover page
Brand
Metso
Category
Other
Document type
Product Leaflet
Language
English
Pages
9
File format
PDF
File size
977 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
FCD12D374F743A3DFE18CCCBB9A6D02C

About this manual

The document is Technical Bulletin 1/19 for Metso Neles Series GW globe control valves. These are 3-way mixing and diverting valves with top and bottom seat guiding, intended primarily for temperature control. The bulletin covers construction, flow directions, trim design, packing, component materials, application limits, ratings, end connections, and rated Cv data.

Standard units use spring diaphragm or cylinder actuators, and ND9000 intelligent valve controllers are listed for auto-calibration and online diagnostics. The text also lists body and trim materials, seat leakage classes, temperature ranges, and accessory options including positioners, limit switches, solenoid valves, transducers, relays, boosters and volume tanks.

What's inside

  • Construction
  • Different flow directions
  • Standard trim design
  • Packing constructions
  • GW, Components and materials
  • GW, Applications guide
  • Flow Direction
  • Flow Positions
  • GW, Ratings & End Connections
  • Rated Cv and Trim Table

Specifications

Valve typeGlobe, 3-way mixing and diverting
Standard seat leakageANSI B16.104 Class II; Class III optional
Pressure classClass 150 to 600
Body materialsCarbon steel or alloy steel; stainless steel also listed
Standard trimCylindrical plug trim
Standard flow characteristicLinear
Actuator optionsSpring diaphragm or cylinder actuators
Digital valve controllerND9000 intelligent valve controllers
End connectionsRF, RTJ, SW, BW

Frequently asked questions

What is the primary application of the GW series?

The primary application is temperature control.

Does the GW valve support both mixing and diverting flow?

Yes. Both diverting and mixing types are available depending on the application.

What is the standard seat leakage class?

The standard seat leakage is ANSI B16.104 Class II, with Class III optionally available.

Which digital valve controller is used with GW valves?

The ND9000 intelligent valve controller is listed for the GW series.

Download PDF (977 KB)

More Metso Manuals