This manual introduces the components, specifications, installation, start-up and troubleshooting of Belt Conveyor System.
This product manual covers the Lubing 60-in width belt conveyor system. It provides system length and capacity information, component and drive/take-up/end/connecting part dimensions, floor support height calculations, recommended clearances, and wall penetration guidance.
The manual also covers component details, assembly and installation, pneumatic setup, belt threading, installation, cutting, splicing, transfer plate and belt scraper adjustment, start-up, belt tracking, troubleshooting, preventive maintenance, inspection schedules, critical spares, belt cleaning, pressure settings, and contact information.
| Belt width | 60 in |
|---|---|
| System lengths and capacity | A: 2000 ft / 609 m; B: 750 ft / 228 m; 700 cases/hr |
| Recommended clearance, drive/take-up unit | 96 in / 2438 mm |
| Recommended clearance, end units/connecting parts | 48 in / 1219 mm |
| End unit support stand height | Transfer height A minus 16.9 in |
| Drive unit/take-up unit support stand height | B minus 25.9 in |
It is a 60-in width belt conveyor system.
Subtract 16.9 in from transfer height A to get end unit support stand height B.
Only water should be used, not a chemical solution.
Adjust it to the lowest pressure possible that does not allow belt slippage on the Drive Roller during peak egg load.