Daikin RHX224SY1P RHX280SY1P RHX335SY1P RHX380SY1P RHX430SY1P Air Conditioner Installation Manual

installation instructions for daikin air conditioner


Daikin RHX224SY1P RHX280SY1P RHX335SY1P RHX380SY1P RHX430SY1P Air Conditioner Installation Manual - cover page
Brand
大金 (Daikin)
Category
Air conditioner
Document type
Installation Guide
Language
Chinese
Pages
20
File format
PDF
File size
6.8 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
404ADDC4E8995462E1C0AC3FEF43BD4B

About this manual

This is the Daikin installation manual (安装说明书) for the RHX224SY1P, RHX280SY1P, RHX335SY1P, RHX380SY1P and RHX430SY1P outdoor air conditioner units. It opens with safety precautions, special notes on the R410A refrigerant, design pressure and disposal of the unit, refrigerant, refrigeration oil and other parts, and then introduces the RHX series units, their combination with Daikin indoor units and the standard accessories supplied.

The body of the manual follows the installation sequence shown in the flow diagram: choosing the installation site, checking and transporting the unit, placing it, removing the transport metal fittings (280 and 335 models only), refrigerant piping and branch kits, field wiring and transmission/power line connection, air tightness test and vacuum drying, pipe insulation, checking the installation, adding refrigerant and test running, field settings, and precautions if refrigerant leaks. This manual is written in Chinese.

What's inside

  • 安全注意事项 (Safety precautions)
  • 特别注意事项 (Special notes: EMC, refrigerant, design pressure)
  • 废弃物的处理 (Disposal)
  • 介绍 (Introduction and combination of units)
  • 选择安装位置 (Selecting the installation site)
  • 空调机的检查与搬运 (Checking and transporting the unit)
  • 空调机的安放 (Placing the unit)
  • 运输用金属件的拆卸 (Removing transport metal fittings)
  • 制冷剂配管 (Refrigerant piping)
  • 现场配线 (Field wiring)

Specifications

RefrigerantR410A
Design pressure4.0 MPa / 40 bar
Rated cooling capacity22.4 to 43.0 kW
Rated heating capacity25.0 to 47.0 kW
RHX224SY1P indoor unit total capacity / maximum number of indoor units112 to 290 / 13 units
RHX280SY1P indoor unit total capacity / maximum number of indoor units140 to 365 / 16 units
RHX335SY1P indoor unit total capacity / maximum number of indoor units165 to 435 / 19 units
RHX380SY1P indoor unit total capacity / maximum number of indoor units190 to 495 / 22 units
RHX430SY1P indoor unit total capacity / maximum number of indoor units215 to 560 / 25 units
EMC classificationClass A product

Frequently asked questions

What refrigerant is used in the Daikin RHX series units?

The unit uses R410A refrigerant, and it must be connected to R410A indoor units.

How should R410A refrigerant be added?

Because R410A is a mixed refrigerant, it must be added while the refrigerant is in liquid state.

How many indoor units can be connected to the RHX430SY1P?

The total indoor unit capacity can range from 215 to 560, with up to 25 indoor units.

What should the user do with the installation manual after installation?

The user should keep the installation manual together with the operation manual in a safe place.

Download PDF (6.8 MB)