This document is the user manual of MAX Induction® Warmer, which mainly introduces the product's usage methods and precautions
This is the Installation & Operation Manual for the Spring USA MAX Induction® Warmer, covering models SM-651R and SM-653R (the international plug version). It explains which serving vessels may be used, the ventilation and dedicated power the installed location needs, how to mount the control panel using the supplied template and screws, and how to flush-mount the range into a countertop with the furnished mounting bracket and leveling screws.
Operating instructions describe the On/Off button, the LED indicators for the Low, Low-Med, Med-High and High settings with their temperature ranges, and the automatic shut-down when no vessel is placed on the unit. A table of induction range error codes lists the flashing-light patterns, their causes and the suggested solutions, and a specification table gives voltage, amperage, peak power and plug type for each model. Safety notes cover cabinet temperature limits, air intake cleaning, service and warranty.
| SM-651R power supply | 110-120 Volts / 5.4 Amps, 650 Watts, 50-60 Hz, NEMA 5-15 plug |
|---|---|
| SM-653R power supply | 230-240 Volts / 2.7 Amps, 650 Watts, 50-60 Hz, CEE-7 Euro Plug or BS 1363 UK Plug |
| Temperature settings | Low 145-155°F (61-71°C); Low-Med 156-165°F (72-76°C); Med-High 166-175°F (77-82°C); High 176-185°F (83-87°C) |
| Minimum vessel diameter | Greater than 9 inches |
| Ventilation clearance under range | At least 7 inches of space |
| Maximum cabinet inside temperature | 90°F / 32°C |
| Counter or table thickness | Must not exceed 2 inches |
| Minimum spacing between multiple ranges | At least 4 inches apart |
| Control panel cutout size | 5-¾” x 2-¾” |
| Automatic shut-down | Shuts down if no vessel is placed on the range after two and a half minutes |
All serving vessels must be induction-ready, have a flat bottom to make full contact with the surface, and be more than 9 inches in diameter. Footed or ridged pieces and glass cookware are not suited for the system.
The range does not detect a pan on the range. Place an induction-ready pan on the range.
As a safety feature it will automatically shut down if a vessel is not placed on it after two and a half minutes.
There must be at least 7 inches of space available under a mounted induction warmer, the cabinet should have intake and exhaust vents, and the inside cabinet temperature must not exceed 90°F / 32°C.