This manual is the instruction manual for EWS Weigele Varia V5, which introduces how to use the product.
The EWS Varia V5 manual explains how to clamp a Varia insert in the tool and how to remove it. It states that the clamping ring must be fully open before assembly, that the insert can be fitted in three positions shifted by 120°, and that the Varia screw is tightened clockwise with 10 Nm.
The manual also describes removal using the integrated mechanical expulsion system and instructs users to oil the insert and tool after cleaning for corrosion prevention. It lists accessories including the UMB100 universal assembly block, MW-V5 changeable tool adaptor, MB-V5 EWS Varia assembly block and a torque wrench, and shows Varia insert types such as collet chuck Morse taper adaptor, Weldon/whistle notch insert, floating toolholder collet chuck, Millering insert and Hydrodehn insert.
| Tool change time | 20 seconds |
|---|---|
| Tightening torque | 10 Nm |
| Insert mounting positions | 3 positions, shifted by 120° |
A tool change takes only 20 seconds, according to the manual cover.
The Varia screw is tightened clockwise with 10 Nm.
The insert can be assembled in 3 positions, respectively shifted by 120°.
Open the clamping ring by turning the Varia screw anti-clockwise. The integrated mechanical expulsion system pushes the insert from the plane face.