This file is an instruction manual for a water purifier, which mainly introduces the use, installation and maintenance methods of the water purifier.
This technical manual is for the Erie Water Treatment Oxydizer water filter for iron, manganese and hydrogen sulfide. It states that the filter removes specific undesired substances and will not purify polluted water or make it safe to drink.
The manual covers warnings and safety, operating conditions and requirements, installation, start-up, the electronic control panel, maintenance, hydraulic flow diagrams, troubleshooting, electrical wiring, default parameter settings, exploded views and technical data.
| pH for iron removal | 6,8 - 9,0 |
|---|---|
| pH for manganese removal | 8,0 - 9,0 |
| pH for iron and manganese removal | 8,0 - 8,5 |
| Maximum iron (Fe2+) | 15 mg/L |
| Maximum manganese (Mn2+) | 2 mg/L |
| Maximum hydrogen sulfide (H2S) | 5 mg/L |
| Maximum organic matter | 4,0 mg/L |
| Maximum chlorine | 1,0 mg/L |
| Operating pressure | min. 1,4 / max. 8,3 bar |
| Optimal operating pressure | 3 bar (±½ bar) |
| Operating temperature | min. 4 / max. 38 °C |
| Electrical connection | 230V-50Hz |
| Operating voltage | 24VAC |
| Transformer | 230/24V-50Hz |
| Drain hose diameter | 13 mm |
| Air gap pipe size | 32 mm pipe |
| Minimum piping to water heater | 3 m |
No. It removes specific undesired substances and will not purify polluted water or make it safe to drink.
The system is configured to perform optimally at 3 bar (±½ bar), with an operating pressure range of 1.4 to 8.3 bar.
No. It is strongly recommended to postpone the start-up regeneration by 24 hours.
The filter works on 24VAC and is equipped with a 230/24V-50Hz transformer; the electrical connection is 230V-50Hz.