This is a manual for a Stelpro SFEX electric heater
This manual is for Stelpro SFE, SFEX and SFECM electric furnaces. It describes models with heating capacities from 10 to 30 kW that are suitable for horizontal, upflow and downflow operations.
It includes important instructions for safe installation by a qualified person and connection by a certified electrician, plus furnace location and clearance, ducts and filters, plenum temperature control, optional accessories, and electrical connections for the furnace and thermostat.
| Heating capacity range | 10 to 30 kW |
|---|---|
| Clearance in front of unit | 24 in. (60 cm) minimum |
| Plenum temperature default setpoint | 60°C (140°F) |
| Plenum temperature setpoint range | 40°C (104°F) to 70°C (158°F) |
| Power supply | 240 or 208 VAC |
| Duct clearance for 27.5 kW and higher models | 1-inch clearance for the first 36 inches |
It must be installed by a qualified person and connected by a certified electrician according to the electrical and building codes in your region.
The furnace must be connected to a 240 or 208 VAC power source.
The default factory setpoint is 60°C (140°F).
A clearance of 24 in. (60 cm) minimum is required in front of the unit.