This manual describes the installation and operation steps of CRIGHTON fuel stove
This Crighton Magnum P100 Installation & Operation Manual explains pre-assembly, assembly, and installation of a solid fuel space heater (wood burner). It notes that a permit is required for any installation and that dimensions comply with the required standards of New Zealand (AS/NZS 2918:2001).
It also gives hearth requirements, safety warnings, and operating instructions for lighting, maintaining, and rekindling a fire. The manual states that the fire should be loaded from front to rear only and that dry seasoned timber should be used.
| Model | Magnum P100 |
|---|---|
| Appliance type | Solid fuel space heater (wood burner) |
| Installation standard | AS/NZS 2918:2001 |
| Floor protector requirement | Non-insulated floor protector (or Hearth) |
| Flue pipe minimum length | 4.0 m |
| Flue joint fixings | Minimum of 3 fixings at each joint |
| Appliance fixing to floor protector | Two 8mm x 50mm dynabolts |
| Preheat time | Approximately 1 hour |
| Heating type | Part radiant, part convection heater |
Yes. A permit is required for any installation of a solid fuel space heater (wood burner) and is obtained through the local council.
Use dry seasoned timber. Do not burn wet timber or chemically treated timber.
No. The appliance should not be operated with a cracked glass.
Load the Magnum P100 clean air fire from front to rear only.