MARANTZ CD5004/N1B/N1SG U1B/K1SG/K1B CD Player Service Manual

This is a user manual for a CD player, which contains information about how to use the product, maintain the product and order parts


MARANTZ CD5004/N1B/N1SG U1B/K1SG/K1B CD Player Service Manual - cover page
Brand
Marantz
Category
Player
Document type
Service Manual
Language
English
Pages
68
File format
PDF
File size
16.1 MB
Published
31 October, 2023
Updated
31 October, 2023
Model
CD5004
MD5 checksum
37CD4F7E6B2E42B7D6C1F10C03A76CBE

About this manual

This is the service manual for the Marantz CD5004 CD player, covering versions U1B, K1SG and K1B. It is published by D&M Holdings Inc. (copyright 2010) and is intended to be used together with the operating instructions; specifications and design are subject to change without notice.

The manual contains service-oriented information including safety precautions and leakage current checks, instructions for ordering original Marantz parts from national subsidiaries and agents, notes for reading the schematic diagrams and parts lists (resistor, capacitor and fusible resistor coding), and a list of abbreviations and marks used in the documentation.

What's inside

  • Safety Precautions
  • Leakage Current Check
  • Shock, Fire Hazard Service Test
  • Ordering Parts
  • Note for Schematic Diagram
  • Note for Parts List
  • Abbreviation and Marks
  • Note on Fuse
  • Note on Safety for Fusible Resistor

Frequently asked questions

What leakage current limit applies when servicing the Marantz CD5004?

If the leakage current exceeds 0.5 milliamps, or the resistance from chassis to either side of the power cord is less than 460 kohms, the unit is defective.

What check must be done before returning the unit to the customer?

Either a leakage current check or a line-to-chassis resistance check must be performed, and any resistance measurement below 1 Megohm requires repair before AC power is applied.

Which fuse should be used for parts code OOMFS20xxx2xx?

Replace only with the Wickmann-Werke GmbH Type 372 non glass type fuse.

Which parts must be replaced with original designated parts?

Parts marked with the /\ symbol have critical safety characteristics (fire and voltage resistance) and must be replaced only with the designated original parts.

Download PDF (16.1 MB)