Beijing Huayirui Technology Co., Ltd. is a high-tech enterprise established in 2007 with 60 employees. It serves the fields of meteorology, hydrology, environmental protection, scientific research, agriculture, energy, national defense, etc., and provides field calibration of ecological meteorological instruments, observation manuals and observation specifications, calibration cycles, data acquisition. The calibration of the instrument, etc.
This Chinese presentation, dated 2019-07-25 and published by Beijing Huayirui Technology Co., Ltd. (www.truwel.com), deals with field calibration of ecological meteorological instruments. Its outline lists the verification intervals and requirements found in surface meteorological specifications, several field calibration methods, a mobile calibration and maintenance system, field accuracy verification methods, and calibration of energy balance systems with parallel comparison of gradient systems.
The slides cite Chinese Meteorological Administration and WMO surface observation specifications, the CERN and CFERN long-term observation specifications and LY/T standards, and give typical verification intervals for wind, precipitation, temperature, humidity and pressure sensors. Equipment covered includes the TRU-W starting wind speed calibrator, the TRU-WS wind speed calibrator, the HFP01SC self-calibrating soil heat flux sensor system, rain and snow gauge maintenance, and parallel comparison with HMP155A and WindObserve sensors. This manual is written in Chinese.
| TRU-W verification range | 0 m/s to 10.0 m/s |
|---|---|
| TRU-W wind speed resolution | 0.04 m/s |
| TRU-W maximum permissible error | ±0.05 m/s |
| TRU-WS operating temperature | -20 to 60 °C |
| TRU-WS wind speed detection range | 0.3 to 40 m/s |
| TRU-WS power supply | Mains or lithium battery |
| TRU-WS standby time on battery | not less than 4 h at full load |
| HFP01SC sensitivity | 50 µV/W.m-2 |
| HFP01SC temperature range | -30 to 70 °C |
The verification interval for wind speed and wind direction sensors is generally 2 years.
Humidity sensors are generally verified once a year.
No, fully digitalized stations do not need verification; stations with analog acquisition do.
It covers 0 m/s to 10.0 m/s, with a wind speed resolution of 0.04 m/s.