Discs plate filtration system is a high-efficiency and energy-saving filtration system. The system consists of multiple filters and users can choose filters with different precisions according to their needs. The filtration precision can reach 20μ-600μ. The system adopts microcomputer control and has automatic flushing and backwashing functions, which are easy to use.
This is the Chinese instruction manual for the Duoling (多灵) disc plate filtration system. It covers machine installation, the advantages and features of the filter system, the working principle of disc filtering, the filtering stage, the backwash stage, internal-source backwash, and a two-position three-way valve diagram.
A large part of the document explains the controller: input/output point functions, parameter settings, control requirements and adjustment methods. It also gives daily and periodic inspection and part replacement instructions, precautions, main technical parameters (filter unit data, flow versus disc accuracy table, operating parameters), design specifications for the Duoling filtration system, and an appendix with unit drawings. This manual is written in Chinese.
| Housing material | Reinforced nylon |
|---|---|
| Disc material | PP |
| Filtration accuracy | 20, 50, 80, 100, 120, 150, 200, 300, 400, 520, 600 μm |
| Dimensions (height × width) | 790 mm × 320 mm |
| Working pressure | 0.2 MPa ~ 1.0 MPa |
| pH range | 5 ~ 11.5 |
| Filtration range | 20 ~ 600 μm |
| Optimum backwash pressure | 0.28 MPa – 0.35 MPa |
| Optimum backwash flow | 28 ~ 35 m³/h |
| Optimum backwash time | 10 ~ 20 seconds |
| Backwash water consumption | 50 L – 100 L per single filter unit per backwash |
| Control voltage | 220 V AC input, 24 V DC output |
Disc plates are available in 20, 50, 80, 100, 120, 150, 200, 300, 400, 520 and 600 μm, giving a filtration range of 20 to 600 μm.
The working pressure range is 0.2 MPa to 1.0 MPa and the water temperature must be below 60 °C; temperatures above 65 °C have to be stated in advance.
A single filter unit consumes about 50 L to 100 L of water per backwash, and the optimum backwash time is 10 to 20 seconds.
The optimum backwash pressure is 0.28 MPa to 0.35 MPa and the optimum backwash flow is 28 to 35 m³/h.