Duoling Disc Plate Filtration System Instruction Manual

Discs plate filtration system is a high-efficiency and energy-saving filtration system. The system consists of multiple filters and users can choose filters with different precisions according to their needs. The filtration precision can reach 20μ-600μ. The system adopts microcomputer control and has automatic flushing and backwashing functions, which are easy to use.


Duoling Disc Plate Filtration System Instruction Manual - cover page
Brand
Duoling
Category
Other products
Document type
User Manual
Language
Chinese
Pages
22
File format
PDF
File size
851 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
865EFBB9402C51BAAD67004313782803

About this manual

This is the Chinese instruction manual for the Duoling (多灵) disc plate filtration system. It covers machine installation, the advantages and features of the filter system, the working principle of disc filtering, the filtering stage, the backwash stage, internal-source backwash, and a two-position three-way valve diagram.

A large part of the document explains the controller: input/output point functions, parameter settings, control requirements and adjustment methods. It also gives daily and periodic inspection and part replacement instructions, precautions, main technical parameters (filter unit data, flow versus disc accuracy table, operating parameters), design specifications for the Duoling filtration system, and an appendix with unit drawings. This manual is written in Chinese.

What's inside

  • 机器的安装
  • 过滤系统的优点及特征
  • 机器的特点
  • 叠片过滤的工作原理
  • 过滤阶段的工作原理
  • 反冲洗阶段原理
  • 内源反冲洗设备过滤及反冲洗原理
  • 两位三通阀原理图
  • 控制器的使用(输入/输出点功能、操作与调节)
  • 维护保养

Specifications

Housing materialReinforced nylon
Disc materialPP
Filtration accuracy20, 50, 80, 100, 120, 150, 200, 300, 400, 520, 600 μm
Dimensions (height × width)790 mm × 320 mm
Working pressure0.2 MPa ~ 1.0 MPa
pH range5 ~ 11.5
Filtration range20 ~ 600 μm
Optimum backwash pressure0.28 MPa – 0.35 MPa
Optimum backwash flow28 ~ 35 m³/h
Optimum backwash time10 ~ 20 seconds
Backwash water consumption50 L – 100 L per single filter unit per backwash
Control voltage220 V AC input, 24 V DC output

Frequently asked questions

What filtration accuracy can the system be supplied with?

Disc plates are available in 20, 50, 80, 100, 120, 150, 200, 300, 400, 520 and 600 μm, giving a filtration range of 20 to 600 μm.

What working pressure and water temperature does the filter accept?

The working pressure range is 0.2 MPa to 1.0 MPa and the water temperature must be below 60 °C; temperatures above 65 °C have to be stated in advance.

How much water does a backwash use?

A single filter unit consumes about 50 L to 100 L of water per backwash, and the optimum backwash time is 10 to 20 seconds.

What are the optimum backwash conditions?

The optimum backwash pressure is 0.28 MPa to 0.35 MPa and the optimum backwash flow is 28 to 35 m³/h.