This document describes how to use Aoke cold storage, including pre-installation preparation, installation and usage precautions.
The Aoke cold storage user manual covers preparation, installation, and use of the cold storage, including required three-phase four-wire 380V/50Hz power, floor and space requirements, and temperature settings for fresh-keeping, frozen, and low-temperature storage. It also lists technical parameters, including R404A refrigerant and air-cooled condenser use without water.
The manual explains the MTC5060 microcomputer control box, including manual and automatic operation of the compressor, evaporator fan, and defrost heater, commissioning steps, overcurrent protection adjustment, alarm conditions and silencing, reference parameter settings, conditions for compressor and defrost operation, and maintenance procedures. This manual is written in Chinese.
| Power supply | Three-phase four-wire 380V/50Hz (±10%) |
|---|---|
| Floor load capacity | Not less than 3T/m2 |
| Condenser type | Air-cooled, no water required |
| Fresh-keeping storage temperature | 0 to +5 °C |
| Frozen storage temperature | 0 to -15 °C |
| Low-temperature storage temperature | -10 to -20 °C |
| Refrigerant | R404A |
It requires a three-phase four-wire 380V/50Hz supply within ±10%.
R404A.
In an alarm state, press any key to eliminate the alarm sound, but the display state does not change.
0 to +5 °C.