Yangguang diesel engine self-priming pump is a self-priming and non-blocking sewage pump. It has the advantages of simple structure, good self-priming performance, strong sewage capacity, high efficiency and convenient maintenance. It is the first of its kind in the sewage pump series in China. Its technical performance indicators are leading in China and reach the international advanced level. It has a wide range of application markets and development prospects.
This is the Chinese user manual (用户使用手册) for the ZBC diesel engine self-priming pump from Shanghai Yangguang Pump Manufacturing Co., Ltd. It introduces the pump, lists its features and applications, states the operating conditions and medium limits, and closes with a performance parameter table (流量, 扬程, 功率, 效率) for models from ZBC25-8-15 up to ZBC300-800-14, plus the company's contact address.
According to the manual, the diesel engine and self-priming pump are combined in one unit with optional manual or automatic control. The pump uses an axial return external-mixing design, so it needs no foot valve or priming tank like an ordinary clean-water self-priming pump, yet can handle liquids carrying large solid particles and long fibers. Typical uses named in the text include municipal sewage, flood control and drought relief, pond and river aquaculture, light industry, paper, textiles, food, chemicals, electric power, fiber, pulp and mixed suspensions. This manual is written in Chinese.
| Ambient temperature (application) | ≤ 50 °C |
|---|---|
| Medium temperature | ≤ 80 °C; up to 200 °C on special request |
| Medium pH range | Cast iron 6–9; stainless steel 2–13; fluorine-lined 1–13 |
| Medium density | Not more than 1240 kg/m³ |
| Self-priming height | 4.5–5.5 m (must not exceed the specified value) |
| Total suction pipe length | ≤ 10 m |
| Solids handling | Suspended particle diameter 50% of pump bore; fiber length 5 times the bore |
| Altitude | ≤ 2500 m; higher altitudes require increased engine power |
| Operating ambient temperature | -25 to 55 °C |
| Relative air humidity | 9–95 % |
| Seismic intensity | 7 degrees |
| Listed model range | ZBC25-8-15 through ZBC300-800-14 |
The medium temperature must not exceed 80 °C; with special requirements it can reach 200 °C.
The self-priming height must not exceed the specified 4.5–5.5 m, and the total suction pipe length must be 10 m or less.
For cast iron the pH range is 6–9, for stainless steel 2–13 and for fluorine-plastic lined versions 1–13.
Up to 2500 m; at higher altitudes the engine power must be increased.