SL450A rotary swivel operation manual, mainly introduces the product's technical specifications, structure instructions, installation, operation, lubrication, replacement of packing device, maintenance, inspection and debugging, packing and shipping and other contents.
This is the operation manual for the Goldenman SL450A rotary swivel from Goldenman Petroleum Equipment Co., Ltd. It covers technical specifications, structure instructions, installation, operation, lubrication, replacement of the packing device, maintenance, inspection and debugging, packing and shipping, and a recommended spares list.
The manual instructs users to read it before installing and operating the swivel and to confirm its maximum static loading. It lists a maximum static load of 4500 kN, a maximum speed of 300 r/min, a maximum working pressure of 35 MPa and a design and operation temperature of -20°C (-4°F). It also states that NDT should be conducted regularly on main bearing parts including the housing, central pipe, bail and bail pin.
| Max. static load | 4500 kN |
|---|---|
| Max. RPM | 300 r/min |
| Max. working pressure | 35 MPa |
| Central pipe ID | Ø75 mm |
| Sub connection | 65/8 REG L.H. |
| Gooseneck connection | 4 LP API Std5B |
| Air motor model | FMS20 |
| Air pressure | 0.7-0.9 MPa |
| Air consumption | 20 m3/min |
| Spinning speed | 92 rpm |
| Brake torque | 2940 N.m |
| Weight | 3310 kg |
The maximum static load is 4500 kN.
The manual lists L-CKC150 for winter and L-CKC220 for summer.
Replace the lubrication oil every 2 months or every 200 hours for new and repaired swivels.
Use adjusting shims to ensure the axial clearance is within 0.05 mm to 0.25 mm.