This manual introduces the purpose, technical parameters, appearance and size, installation, operation and maintenance of thread pressure reducing valve.
This two-page manual describes the Norika PRVCRN series threaded pressure reducing valve, a valve used to reduce the pressure in a water pipeline and keep it within a constant range. It explains how the valve is installed and adjusted, how the built-in filter is cleaned, and what precautions to observe during maintenance. Technical parameters, available port sizes and the main valve components are also listed.
The document is bilingual: page 1 is in Chinese and page 2 gives the English text for installation, operation and maintenance, the special precautions, the use of the valve, the technical parameters and the appearance and dimension table for models PRVCRN15 through PRVCRN65. Pressure is adjusted with the hexagonal head, and an outlet pressure gauge can be fitted after removing the plug head. This manual is written in Chinese.
| Nominal Pressure | 1.6 MPa |
|---|---|
| Medium | Water |
| Working Temperature | 0 °C < t ≤ 90 °C |
| Outlet Pressure Adjustable Range | 0.15 – 0.45 MPa |
| Pressure Gauge Port Thread | G1/4" |
| Valve Body Thread Ends | G1/2" (PRVCRN15/20) up to G2 1/2" (PRVCRN65), depending on model |
Turn the hexagonal head (5) clockwise to increase the outlet pressure; turning it counterclockwise reduces the pressure.
Yes. The valve can be installed horizontally or vertically in the pipeline, as long as the arrow on the body matches the flow direction.
A pressure gauge with an outer diameter of 60 mm is recommended at the end of the valve.
Remove the hexagonal bonnet (3) and the internal valve assembly (6), take out the filter (7) for cleaning and install it back to reuse.