TH320 Universal Rockwell Hardness Tester is a multi-function hardness tester, which adopts the Rockwell measurement principle and can directly carry out Rockwell hardness measurement, surface Rockwell hardness measurement, plastic Rockwell hardness measurement, and convert Rockwell hardness values into HB, HV, HLD, HK, σb values. It is suitable for carbon steel, alloy steel, cast iron, non-ferrous metals and engineering plastics, and has the characteristics of high testing accuracy, wide measurement range, automatic loading and unloading of main test force, digital display of measurement results and automatic printing or communication with external computers.
This document provides detailed instructions for operating the TH320 universal Rockwell hardness tester, including setup, calibration, test procedures, and maintenance. It covers both Rockwell and surface Rockwell hardness measurements, with features such as automatic load/unload, data statistics, and curve correction. The device supports multiple scales and can convert results to HB, HV, HLD, HK, and σb values. It is designed for use in industries like metallurgy, mechanical manufacturing, and quality control.
The manual includes sections on installation requirements, adjustment procedures, operation modes, parameter settings, auxiliary functions, and troubleshooting. It also provides technical specifications such as measurement resolution (0.1HR), operating temperature (10°C–35°C), and power requirements (220V/110V). This manual is written in Chinese.
| Measurement Resolution | 0.1HR |
|---|---|
| Operating Temperature | 10℃~35℃ |
| Net Weight | 100kg |
| Maximum Dimensions | 720mm×240mm×815mm |
It can measure 30 scales including HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRP, HRR, HRS, HRV, HR15N, HR30N, HR45N, HR15T, HR30T, HR45T, HR15W, HR30W, HR45W, HR15X, HR30X, HR45X, HR15Y, HR30Y, HR45Y.
The instrument is suitable for hardness detection of materials including carbon steel, alloy steel, cast iron, non-ferrous metals, and engineering plastics.
The working temperature range is 10℃ to 35℃.
The platform must have a load-bearing capacity greater than 150kg.