This manual describes the features and characteristics, installation, operation, maintenance, etc. of VAT Vakuumventile AG 121 series vacuum gate valve double acting pneumatic drive.
This manual covers the VAT 121 Series vacuum gate valve with double acting pneumatic drive, intended for clean dry vacuum applications. It describes product identification, safety, design and function, installation, operation, maintenance, repair, disassembly, storage, packaging, transport, disposal, and spare parts.
The valve uses VATLOCK sealing technology and is available for nominal diameters from DN 63 to DN 320 mm. Installation and maintenance instructions include allowed forces and moments, compressed air and electrical connections, troubleshooting, seal replacement, tightening torques, and spare part lists. This manual is written in Chinese.
| Nominal diameter | DN 63–320 mm (2½"–12") |
|---|---|
| Allowed axial force and bending moment, DN 63 | 980 N axial force; 39 Nm bending moment |
| Valve cover screw tightening torque, DN 63–100 | 3.5 Nm |
Clean dry vacuum applications only; use for other purposes requires prior written permission from VAT.
Only certified personnel may perform these operations.
Remove hazardous substances such as toxic, corrosive, or microbial substances from the valve.
The valve must always be transported using original packaging materials.