VAT 121 Series Vacuum Gate Valve Double Acting Pneumatic Drive Installation, Operation and Maintenance Manual

This manual describes the features and characteristics, installation, operation, maintenance, etc. of VAT Vakuumventile AG 121 series vacuum gate valve double acting pneumatic drive.


VAT 121 Series Vacuum Gate Valve Double Acting Pneumatic Drive Installation, Operation and Maintenance Manual - cover page
Brand
VAT
Category
Other products
Document type
User Manual
Language
Chinese
Pages
27
File format
PDF
File size
538 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
DAC27E750843CB7EC28894FDBC270933

About this manual

This manual covers the VAT 121 Series vacuum gate valve with double acting pneumatic drive, intended for clean dry vacuum applications. It describes product identification, safety, design and function, installation, operation, maintenance, repair, disassembly, storage, packaging, transport, disposal, and spare parts.

The valve uses VATLOCK sealing technology and is available for nominal diameters from DN 63 to DN 320 mm. Installation and maintenance instructions include allowed forces and moments, compressed air and electrical connections, troubleshooting, seal replacement, tightening torques, and spare part lists. This manual is written in Chinese.

What's inside

  • Product description
  • Safety
  • Design and function
  • Installation
  • Operation
  • Maintenance
  • Repair
  • Disassembly and storage
  • Packaging and transport
  • Disposal

Specifications

Nominal diameterDN 63–320 mm (2½"–12")
Allowed axial force and bending moment, DN 63980 N axial force; 39 Nm bending moment
Valve cover screw tightening torque, DN 63–1003.5 Nm

Frequently asked questions

What applications is the valve intended for?

Clean dry vacuum applications only; use for other purposes requires prior written permission from VAT.

Who is allowed to install and service the valve?

Only certified personnel may perform these operations.

What must be done before returning the valve to VAT?

Remove hazardous substances such as toxic, corrosive, or microbial substances from the valve.

What packaging is required for transport?

The valve must always be transported using original packaging materials.