Yaoxidakai EPDT-285b SY-5 Type Filter User Manual

The SY-5 filter is a filter product produced by the Yaoshidake pressure reducing valve company. This product is mainly used in steam, air, cold and hot water, oil and other non-hazardous fluid pipelines, and can effectively filter impurities, iron slag and other foreign objects.


Yaoxidakai EPDT-285b SY-5 Type Filter User Manual - cover page
Brand
耀希达凯
Category
Other device
Document type
User Manual
Language
Chinese
Pages
7
File format
PDF
File size
213 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
2A29B341D3533B91B632C6828ACAFFC9

About this manual

This manual is for the Yaoxidakai EPDT-285b SY-5 type filter. It describes a filter widely used for dust removal in various pipelines, installed especially at the front of pressure-reducing valves, temperature control valves, solenoid valves, and steam traps.

It lists applicable fluids, maximum pressure and temperature, materials, connection type, dimensions and weights for sizes 10A to 50A, operation, caliber selection, maintenance and inspection, disassembly, cleaning and assembly, and piping examples. The standard mesh is 80 mesh, with 20 to 100 mesh available on request. This manual is written in Chinese.

What's inside

  • Preface
  • Operating Parameters
  • Dimensions and Weight
  • Operation Description
  • Caliber Selection
  • Maintenance and Inspection
  • Disassembly, Cleaning and Assembly
  • Piping Examples
  • After-Sales Service

Specifications

Applicable fluidsSteam, air, cold and hot water, oil, other non-hazardous fluids
Maximum pressure2.0 MPa
Maximum temperature220℃
Valve body materialDuctile cast iron
Optional mesh sizes20 to 100 mesh
Controlled differential pressure0.1 MPa or below

Frequently asked questions

What fluids can the EPDT-285b filter be used for?

Steam, air, cold and hot water, oil, and other non-hazardous fluids.

How should the filter mesh be cleaned?

After confirming there is no pressure inside the valve body, remove the cap and the mesh and rinse them with compressed air or water.

In which direction should the filter be installed?

Install the filter with the cap facing down. If the fluid is steam, connect the piping with the cap facing the side to reduce condensate accumulation.