This SDS provides chemical safety information about the Duster™ Aerosol Dust Removal System, including GHS classification information, safety label elements, precautionary statements, accident response, safe storage, and waste disposal information.
This document is a Chinese-language safety data sheet for the Duster™ Aerosol Dust Removal System, product codes 14085 and PR14085, from CRC Industries Trading (Shanghai) Co., Ltd. It was published on 28 October 2014, revised on 27 March 2015, and is version 02.
The sheet identifies the product as a liquefied, pressurized gas for dust removal and lists a mixture containing 100% 1,1,1,2-tetrafluoroethane (CAS 811-97-2). It covers hazard identification, first aid, firefighting, accidental release, handling and storage, and exposure controls. This manual is written in Chinese.
| Product Name | Duster™ Aerosol Dust Removal System |
|---|---|
| Product Code | 14085, PR14085 |
| Manufacturer | CRC Industries Trading (Shanghai) Co., Ltd. |
| Composition | 1,1,1,2-tetrafluoroethane (CAS 811-97-2), 100% |
| GHS Classification | Liquefied gas; pressurized gas |
| Physical Hazard | Contains gas under pressure; may explode if heated |
| Storage Temperature Limit | Do not store above 120°F/49°C |
It is recommended for dust removal.
It is a mixture containing 100% 1,1,1,2-tetrafluoroethane (CAS 811-97-2).
Immediately flush with plenty of water for 15 minutes if there is liquid contact or direct spray; seek medical advice if frostbite symptoms persist.
Do not expose it to heat or store it above 120°F/49°C.