CW-1200 lightning equipotential connection transition resistance tester is produced by Nanjing Changwo Electric Technology Co., Ltd. It is a instrument for testing equipotential connection and transition resistance of lightning protection system. The product is simple and convenient to operate, with high accuracy, fast testing speed, good repeatability and intuitive reading, which greatly facilitates the development of test projects and improves work efficiency.
The CW-1200 is a Changwo equipotential transition resistance tester intended for equipotential bonding and transition resistance checks in lightning protection work. The manual describes its use for checking connections such as surge protective device ground wires to equipotential bonding bars, grounding wires in structured cabling, shielded enclosures, and air terminals to metal objects. It states a test current range of 0.2 A to 1 A, a resolution of 1 mΩ, and accuracy not lower than class 1.0.
The manual covers quality warranty, safety requirements, product features, main technical parameters, assessment of measurement results, operation, charging, and standard accessories. It also lists a 12 V lithium iron phosphate battery, a 240 × 160 monochrome LCD, storage for up to 1000 records, and dimensions of 330 × 280 × 140 mm. This manual is written in Chinese.
| Test Current | 0.2–1 A (max 1.2 A), continuously adjustable in 0.1 A steps |
|---|---|
| Measurement Accuracy | 200 mΩ ±1%; 0.2 Ω to 20 Ω ±2% |
| Measurement Radius | 0 to 15 m |
| Display | 240 × 160 monochrome LCD |
| Power Supply | 12 V dedicated lithium iron phosphate battery |
| Operating Environment | -10 °C to +50 °C; humidity ≤ 90% |
| Dimensions | 330 × 280 × 140 mm |
| Data Storage | Up to 1000 measurement records |
It is used for equipotential bonding and transition resistance testing in lightning protection systems, including checking connections between surge protective device ground wires and equipotential bonding bars.
It is continuously adjustable from 0.2 A to 1 A, with a maximum of 1.2 A, in 0.1 A steps.
It can store up to 1000 measurement records.
It shows only “>60” and does not display a specific value.