Sichuan Province VOCs Control Technical Manual Part 9 Construction Machinery

This technical manual gives the requirements for VOCs emission control in 14 key industries, including petrochemical industry, for reference of enterprises.


Sichuan Province VOCs Control Technical Manual Part 9 Construction Machinery - cover page
Brand
Sichuan Provincial Department of Ecology and Environment
Category
Other
Document type
Other
Language
Chinese
Pages
32
File format
PDF
File size
1.3 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
0DF0A4A07637232881F19E3AD3588DFF

About this manual

This document is a technical manual issued by the Sichuan Provincial Department of Ecology and Environment and the Sichuan Academy of Environmental Sciences. It serves as a guide for enterprises in the construction machinery manufacturing sector to control volatile organic compound (VOCs) emissions in compliance with national and local regulations. This manual is written in Chinese.

What's inside

  • Source Reduction
  • Process Control
  • End-of-Pipe Treatment
  • Emission Limits
  • Monitoring and Control
  • Record Keeping

Specifications

VOCs content limit for solvent-based primer≤540 g/L
Minimum removal efficiency for end-of-pipe facilities80%
Maximum allowable VOCs concentration for open sprayingProhibited
Maximum allowable VOCs concentration for unorganized emissions (routine)2.0 mg/m3

Frequently asked questions

What is the VOCs content limit for water-based primer?

The limit is ≤300 g/L.

Can open spraying and drying operations be performed?

No, open spraying and drying operations are prohibited except for special tasks like local repairs on large cranes.

What is the minimum removal efficiency required for end-of-pipe treatment facilities?

The efficiency should not be lower than 80%.

How should VOCs materials be stored?

VOCs materials must be stored in a sealed manner, either indoors or in a dedicated site with rain shelters, sunshades, and anti-seepage facilities.

Download PDF (1.3 MB)