Meiji FINER-FORCE P08/P10/P13 Hand Spray Gun Operation Manual

This manual introduces the safe operating methods of using Meiji hand spray guns


Meiji FINER-FORCE P08/P10/P13 Hand Spray Gun Operation Manual - cover page
Brand
Meiji
Category
Other
Document type
User Manual
Language
English
Pages
1
File format
PDF
File size
1.3 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
EE55EE48A5D0EE66FC02EABE01ED1EEF

About this manual

The Meiji Hand Spray Gun operation manual explains safety precautions for spray work, including fire prevention, solvent compatibility, grounding, ventilation and protective gear. It also covers installation, the list of components, operation procedure, maintenance and inspection, specifications and parts replacement.

The specifications section lists the FINER-FORCE-P08, FINER-FORCE-P10 and FINER-FORCE P13 models. The manual gives operating guidance for spraying pressure, spraying distance, air volume, pattern adjustment and paint volume adjustment.

What's inside

  • WARNING/CAUTION
  • Protection of Human Body
  • Improper Handling of Equipment
  • Other Precautions
  • Installation
  • List of Components
  • Operation Procedure
  • Maintenance and Inspection
  • Specifications
  • Parts Replacement

Specifications

Maximum operating pressure0.69 MPa
Appropriate spraying pressure0.15 to 0.25 MPa
Appropriate spraying distance150 mm to 250 mm
Air/paint connection boreG1/4
Noise level80 dB (A) or higher depending on use condition or work environment

Frequently asked questions

What is the maximum operating pressure for the Meiji hand spray gun?

The maximum operating pressure is 0.69 MPa. Do not use the spray gun at a pressure higher than this.

What spraying distance should be used?

The appropriate spraying distance is between 150 mm to 250 mm.

Can a halogenated hydrocarbon solvent be used to clean the spray gun?

No. A halogenated hydrocarbon solvent can cause the spray gun body aluminum parts to crack or melt.

Download PDF (1.3 MB)

More Meiji Manuals