This document introduces the application field, working principle and main technical parameters of the LDG electromagnetic flowmeter.
This manual covers the LDG L-magB electromagnetic flowmeter made by Hangzhou Yikong Technology Co., Ltd. It explains the working principle based on Faraday's law of electromagnetic induction and lists product features such as a backlit LCD display, Chinese menu operation, and RS485, Hart and Modbus outputs. It also describes application areas including chemical, food, paper, water supply and wastewater industries.
The document gives main technical parameters, converter operation and wiring, instrument parameter settings, infrared handheld keyboard use, alarm and fault handling, and installation requirements. It includes selection guidance for sensor diameter, electrode, grounding ring and lining materials, as well as flow range tables. This manual is written in Chinese.
| Accuracy grade (pipeline type) | 0.5, 1.0 |
|---|---|
| Flow velocity range | 0.1-15 m/s |
| Fluid conductivity range | ≥5 us/cm (integrated type) |
| Power supply | 85-265V / 45-63HZ or DC24V |
| Straight pipe length (pipeline type) | Upstream ≥5DN, downstream ≥2DN |
| Rated working pressure | DN10-DN250: ≤1.6 MPa |
| Total power consumption | Less than 20W |
| Measured medium temperature (PTFE lining) | -20 to +120°C |
The flow measurement range corresponds to a velocity range of 0.1 to 15 m/s.
The pipeline type has accuracy grades of 0.5 and 1.0.
The power supply is 85-265V / 45-63HZ or DC24V.
For the pipeline type, the upstream straight pipe length is at least 5DN and the downstream length is at least 2DN.