Hangzhou Yikong LDG L-magB Electromagnetic Flowmeter Instruction Manual

This document introduces the application field, working principle and main technical parameters of the LDG electromagnetic flowmeter.


Hangzhou Yikong LDG L-magB Electromagnetic Flowmeter Instruction Manual - cover page
Brand
杭州逸控科技有限公司
Category
Electromagnetic Flowmeter
Document type
User Manual
Language
Chinese
Pages
49
File format
PDF
File size
2.4 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
EF204113405211008B7D13DBA6E5385C

About this manual

This manual covers the LDG L-magB electromagnetic flowmeter made by Hangzhou Yikong Technology Co., Ltd. It explains the working principle based on Faraday's law of electromagnetic induction and lists product features such as a backlit LCD display, Chinese menu operation, and RS485, Hart and Modbus outputs. It also describes application areas including chemical, food, paper, water supply and wastewater industries.

The document gives main technical parameters, converter operation and wiring, instrument parameter settings, infrared handheld keyboard use, alarm and fault handling, and installation requirements. It includes selection guidance for sensor diameter, electrode, grounding ring and lining materials, as well as flow range tables. This manual is written in Chinese.

What's inside

  • Product Features
  • Overview and Working Principle
  • Main Technical Parameters
  • Flowmeter Instructions
  • Technical Performance Indicators
  • Flowmeter Model Selection
  • Converter Operation
  • Instrument Parameter Settings
  • Flowmeter Alarms and Fault Handling
  • Installation Location and Requirements

Specifications

Accuracy grade (pipeline type)0.5, 1.0
Flow velocity range0.1-15 m/s
Fluid conductivity range≥5 us/cm (integrated type)
Power supply85-265V / 45-63HZ or DC24V
Straight pipe length (pipeline type)Upstream ≥5DN, downstream ≥2DN
Rated working pressureDN10-DN250: ≤1.6 MPa
Total power consumptionLess than 20W
Measured medium temperature (PTFE lining)-20 to +120°C

Frequently asked questions

What is the flow velocity measurement range of the LDG electromagnetic flowmeter?

The flow measurement range corresponds to a velocity range of 0.1 to 15 m/s.

What accuracy grades are available for the pipeline type?

The pipeline type has accuracy grades of 0.5 and 1.0.

What power supply does the flowmeter use?

The power supply is 85-265V / 45-63HZ or DC24V.

What straight pipe length is required for the pipeline type?

For the pipeline type, the upstream straight pipe length is at least 5DN and the downstream length is at least 2DN.