This document introduces the knowledge of centrifugal pump and pipeline energy saving, including centrifugal pump efficiency standard, motor efficiency standard, pump performance curve, flow power, power consumption and power consumption ratio, pipeline impedance curve and flow power, how to use energy consumption ratio to check pump operation status, variable frequency centrifugal pump energy saving practical methods, etc.
Page 1 identifies this as a presentation titled "離心泵與管路節能實務" by 簡煥然, consultant at 煜然有限公司, dated 2012.10.31. It lists sources including the ITRI high-efficiency motor program, 自來水, and pump makers Grundfos, 三錦泵浦, 萬事興泵浦 and 協磁泵浦.
The outline covers centrifugal pump and motor efficiency standards, Eup/Erp directives, pump performance curves, flow work, power consumption and energy consumption ratio, piping resistance curves, checking pump operation with the energy consumption ratio, variable-frequency centrifugal pump practices, and appendices on pump parameters and land pump energy-ratio data. This manual is written in Chinese.
It uses unit output flow work and input electrical work as the basis for energy-consumption evaluation.
Yes. The text says variable-speed drive is included as one solution to energy-consumption issues.
The outline cites CNS 2138/B4004 for small volute pumps.
A efficiency means the pump's rated-point efficiency must be higher than the A efficiency; B efficiency means the operating-range efficiency must be higher than the B efficiency.