This document introduces the use of the low environment temperature air source heat pump (cold water) unit of Bilian Energy Saving, installation method, debugging method, maintenance method, etc.
This is the Chinese installation and use manual (document code SMS-C1015, 变频/variable frequency version) for the household low ambient temperature air source heat pump (chilled water) unit from Guangdong Bilian Energy Saving Equipment Co., Ltd. The manual covers the models RB-22KC3GBP, RB-22KC3GDBP, RB-22KC2GBP, RB-10KC2GDBP, RB-18KC2GDBP, RB-22KC2GDBP and RB-32KC2GDBP.
It explains the reverse Carnot cycle the heat pump works on, lists the Chinese standards the product follows, shows outline drawings, performance tables (heating and cooling capacity, rated currents, input power, refrigerant charge, noise, dimensions and mass) and performance curves, and describes the control panel keys and how to set temperature, timer, parameters and query codes. It then covers unit and piping installation, electrical installation, preparation for trial running, operation control, maintenance, controller protection functions, fault codes, common fault analysis, after-sales service and warranty, and the electrical wiring diagram. This manual is written in Chinese.
| Heating capacity (RB-22KC3GBP) | 9600 W |
|---|---|
| Cooling capacity (RB-22KC3GBP) | 14000 W |
| Power supply | AC 220 V 50 Hz |
| Rated heating/cooling current (RB-22KC3GBP) | 24.5 / 27.3 A |
| Refrigerant charge (RB-22KC3GBP) | R410A, 2100 g |
| Noise level (RB-22KC3GBP) | 62 dB |
| Waterproof grade | IPX4 |
| Protection against electric shock | Class I |
| Unit dimensions (RB-22KC3GBP) | 950 x 680 x 1380 mm |
| Unit mass (RB-22KC3GBP) | 160 kg |
The units in the performance table run on AC 220 V 50 Hz.
Touch and hold the power/unlock key for about 3 seconds until you hear a beep; if no key is pressed for 60 seconds the keys lock automatically again.
The unit uses R410A; the RB-22KC3GBP is charged with 2100 g.
From the unlocked state, touch the mode key and the plus key together for 3 seconds to enter parameter query, where codes A1 through E6 can be checked.