This manual is the installation manual for the Ultra 2-inch square edgeless recessed lamp (DLN26/MTN26) and the ULTRA TUNABLE 3-inch square edgeless recessed lamp (DLN36/MTN36). It mainly introduces the use, installation, and precautions of the lamp.
This Chinese-language installation guide from WAC Lighting covers the Ultra 2-inch square edgeless recessed lamp (DLN26/MTN26) and the ULTRA TUNABLE 3-inch (DLN36/MTN36) and 4-inch (DLN46/MTN46) square edgeless recessed lamps. Each model section repeats the same installation statement: read the instructions first, have the work done by a qualified electrician, switch off power before installation or maintenance, use the luminaire indoors only (not in damp locations), keep insulation and combustible material off the top of the fixture, and do not mount it on unstable or weak ceilings. The light source is non-replaceable, so the whole luminaire must be replaced when the source reaches end of life.
The lamp installation section gives wiring notes. Where a driver has its own leads that must connect to a separate terminal block (not supplied), each terminal block must measure at least 10×20×25 mm. Luminaires supplied without a driver have flying leads that must not be connected directly to 220 VAC mains: the 2-inch version needs a customer-supplied driver matched to the light source, while the 3-inch and 4-inch tunable versions need a field-supplied DALI DT8 dimming driver (constant current 400 mA max, 36 V typ for 3-inch; 700 mA max, 36 V typ for 4-inch) wired red to W+, black to W-, yellow to C+ and green to C-. A final section covers beam angle adjustment. This manual is written in Chinese.
| Installation environment | Indoor use only, not for damp locations |
|---|---|
| Light source | Non-replaceable; replace the entire luminaire |
| Minimum terminal block size | Not less than 10×20×25 mm per circuit |
| Driver requirement, 3-inch tunable (DLN36/MTN36) | Field-supplied DALI DT8 dimming driver, constant current 400 mA MAX, 36 V Typ |
| Driver requirement, 4-inch tunable (DLN46/MTN46) | Field-supplied DALI DT8 dimming driver, constant current 700 mA MAX, 36 V Typ |
| Lead wire assignment | Red to W+, black to W-, yellow to C+, green to C- |
| Mains connection | Leads must not be connected directly to 220VAC mains |
The instructions require installation by a qualified electrician, and power must be switched off before installation or maintenance.
No. It is intended for indoor installation only and must not be used in damp environments.
No, the light source is non-replaceable; when it reaches end of life the entire luminaire must be replaced.
A field-supplied DALI DT8 dimming driver with constant current 400 mA MAX and 36 V Typ, wired according to the label.