Huade'er Shearing Machine Control System Adjustment Manual

This manual is a Huadel gate shearing adjustment manual, which mainly introduces the characteristics and specifications of the gate shear, the operation panel, the system introduction, auxiliary functions, and the processing interface.


Huade'er Shearing Machine Control System Adjustment Manual - cover page
Brand
华德尔
Category
Automation control Equipment
Document type
Service Manual
Language
Chinese
Pages
19
File format
PDF
File size
763 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
7D0037674FB1C0B61D0431A22800053B

About this manual

This adjustment (debugging) manual from Wuxi Huade'er Automation Control Technology Co., Ltd. describes a shearing machine control system developed for domestic shearing machine requirements. The introduction lists a 64*128 LCD display, full Chinese large-character display with Chinese/English switching, X/Y axis digital display, external switch self-diagnosis, an intelligent error reporting system, an expandable external button option, a standard RS232/485 interface and a single-direction positioning function.

The manual covers specifications (display, axis control characteristics and electrical data, ambient temperature), the operation panel keys and indicator lights, auxiliary functions such as parameter setting with the numerator/denominator calculation, language and metric/inch switching, and the test page for blade clearance, test switches and the test keyboard. It ends with machining interface operating notes, an encoder wiring reference table, J4/J3/J7 interface input/output diagrams, the internal system wiring diagram and common faults and solutions. This manual is written in Chinese.

What's inside

  • Product Introduction
  • Specifications
  • Display
  • Axis Control Characteristics and Electrical Specifications
  • Ambient Temperature
  • Operation Panel Description
  • Auxiliary Functions
  • Parameter Setting and Saving
  • Chinese/English Switching
  • Metric/Inch Conversion

Specifications

Display64*128 LCD display
Controlled axesOne axis (X, Y); X controls back gauge travel, Y only displays the shearing angle
Input voltageDC24V ±2%
Maximum current5A
Operating ambient temperature0 to 45 ℃
Storage ambient temperature0 to 70 ℃
Parameter save passwordThree-digit password 147
Blade clearance passwordThree-digit password 258

Frequently asked questions

How do I enter the auxiliary function interface?

Hold the stop key and then power on the system to enter the auxiliary function interface.

What password is needed to save changed system parameters?

After the system asks for a password, enter the three-digit password 147 to save and return to the parameter setting interface.

How are the numerator and denominator calculated for the axis?

Divide the screw pitch multiplied by 100 by the encoder line count; for a 10 mm pitch and a 400-line encoder the result is 5/2.

Can metric/inch conversion be used on every unit?

No, this function is opened only for export machines.