This is the instruction manual of LP-xxxx explosion-proof LED clean lamp, which is suitable for area 2 and dust danger area 21 and 22, and can be used both indoors and outdoors.
This user manual covers the Langpu Electric LP Series explosion-proof LED clean lamp, a work light for Zone 2 gas hazardous areas and Zone 21/22 dust hazardous areas that can be used indoors and outdoors. According to Zhejiang Langpu Electric Technology Co., Ltd., the lamp is designed, manufactured and tested to ISO9001 and meets GB3836.1-2010, GB3836.8-2014, GB12476.1-2013 and GB12476.5-2013; it is not suitable for Zone 0 or Zone 1 hazardous locations, and any modification that reduces its explosion protection is not permitted.
The document explains the model designation and technical parameters, then walks through stud mounting and ceiling bracket mounting step by step, including cutting the mounting-surface openings (150 mm power supply opening), connecting light and power, single-lamp and multi-lamp wiring diagrams, and sealing the joint between lamp and mounting surface with adhesive. It ends with rules for cable entries and blanking plugs, commissioning checks, maintenance and spare parts, and notes that the lamp may only be wiped with a damp cloth. This manual is written in Chinese.
| Hazardous area application | Zone 2 gas hazardous areas; Zone 21 and 22 dust hazardous areas |
|---|---|
| Protection rating | IP66 |
| Ambient air pressure | 80 kPa (0.8 bar) to 110 kPa (1.1 bar) |
| Ambient oxygen content | 21% by volume (standard air) |
| Relative humidity | Not more than 95% |
| Power supply mounting opening | 150 mm diameter |
In Zone 2 gas hazardous areas and in Zone 21 and 22 dust hazardous areas, indoors and outdoors. It is not suitable for Zone 0 or Zone 1 hazardous locations.
No. The upstream power supply must be disconnected before the cover is opened, and opening the cover while energized is strictly prohibited.
Wipe it only with a damp cloth.
Air pressure of 80 kPa (0.8 bar) to 110 kPa (1.1 bar), air with a standard oxygen content of 21% by volume, relative humidity not above 95%, and a location without significant vibration or insulation-damaging gases and vapors.