Meech 924EX Type DC Impulse Static Eliminator Instruction Manual

The 924EX is a compact DC impulse static eliminator designed to solve the most demanding static elimination applications. Its emitter tips are specially electrically-coupled to provide a shock-free touch whilst delivering superior static neutralization performance.


Meech 924EX Type DC Impulse Static Eliminator Instruction Manual - cover page
Brand
Meech
Category
Other
Document type
User Manual
Language
Chinese
Pages
31
File format
PDF
File size
4.9 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
88F7424FD8B5B8377EDDE4A5965CDFDA

About this manual

The 924EX is described as a compact pulsed DC static eliminator bar for hazardous areas, ATEX approved for Zone 1 use. The document states that it is powered by a Hyperion 233v4 HL pulse DC controller and has resistor-coupled titanium emitter tips, a divider between positive and negative emitters and a T-slot mounting system.

The Chinese instruction manual covers certification, unpacking and inspection, packing list, features and benefits, installation, operation, maintenance, troubleshooting and technical specifications, including output voltage, operating distance and ambient temperature. This manual is written in Chinese.

What's inside

  • Introduction
  • Certification
  • Unpacking and Inspection
  • Packing List
  • Features and Benefits
  • Installation
  • Operation
  • Maintenance
  • Troubleshooting
  • Technical Specifications

Specifications

Dimensions (W x H)22 x 32 mm
Length40 mm increments, between 300-1400 mm
Emitter tip size1 x 10 mm
MaterialPC ABS
Maximum ambient temperature38°C
MountingT-slot with M4 x 20 stud
CableTV20 cable; standard 5 m, other lengths on request
ConnectionGrey HT plug
Power supply233v4HL pulse DC controller
Operating frequencyDefault 20 Hz (1-20 Hz adjustable)
Output voltage5.5 kV
Operating balanceDefault 54% positive, 46% negative (adjustable)
Operating distance20-200 mm
Safety protectionIP68
Ozone contentBelow 0.01 ppm
EX area characteristicsII 2G IIC T4 Gb Ta = -20°C to +38°C

Frequently asked questions

What is the 924EX approved for?

It is ATEX approved for use in Zone 1 applications.

What controller powers the 924EX?

It is powered by a Hyperion 233v4 HL pulse DC controller.

What is the default operating frequency?

The default is 20 Hz, adjustable from 1 to 20 Hz.

What is the standard cable length?

The standard length is 5 m, with other lengths available on request.