Detailed operating manual, introduces the operation method and precautions of MPN type hydraulic power pack.
The HAWE MPN hydraulic power pack is covered by this brief operating manual (pamphlet D 7207, B7207, March 2008-00). It lists standard nominal voltages and mains tolerances, motor versions and data, current consumption, and performance restrictions for operation at reduced supply voltage.
The manual gives notes for installation in customer-furnished tanks, direction of rotation, filling with hydraulic oil, initial operation and bleeding, adjustment of the protective motor switch, servicing and spare parts. Electrical connection is described for 1-phase and 3-phase versions, including HARTING plug and terminal box arrangements, with protection class IP 54 and safety class 1.
| Standard nominal voltages and frequencies | 3+400V 50 Hz; 3+230V 50 Hz; 1+230V 50 Hz; 1+110V 60 Hz; 3+460V 60 Hz |
|---|---|
| Protection class | IP 54 according to DIN EN 60529 / IEC 60529 |
| Safety class | Safety class 1 according to DIN VDE 0100 |
| Hydraulic fluid viscosity range | Min. approx. 4 mm2/s; max. approx. 1500 mm2/s |
| Permissible fluid temperature | Approx. 80 °C |
| Permissible winding temperature | Approx. 130 °C (isolation class B) |
| MPN 42 nominal power | 2.1 kW at 50 Hz; 2.5 kW at 60 Hz |
The complete hydraulic power pack has protection class IP 54 according to DIN EN 60529 / IEC 60529.
No. Any fluid types containing water, such as HEPG and HETG, must not be used.
As a general rule, the fluid should be exchanged every year, and more frequently if tests show aging or contamination.
The permissible fluid temperature is approximately 80 °C; the permissible winding temperature is approximately 130 °C (isolation class B).